How do I fix CSLD rate warning?
Troubleshooting Tips
- Confirm the tank’s thermal coefficient is correct. An incorrect thermal coefficient can cause the console to see inaccurate fuel volumes.
- Confirm the tank’s CSLD climate factor is set to Moderate. When set to Extreme, the displayed leak rate will be substantially increased.
What does CSLD increase rate warning mean?
The CSLD rate increase warning that you asked about is an alarm to indicate that the tank volume is going up when there is no delivery.
What is CSLD test results?
Highly Accurate Leak Detection Continuous Statistical Leak Detection (CSLD) is a certified leak-testing technology that continuously monitors fuel height and temperature to detect quiet periods in the underground storage tank and collect leak-detection data during idle time in a database.
What does no CSLD idle time mean?
No CSLD Idle Time Warn- ing T System has not had enough idle time over previ- ous 24 hours to run a statistical leak detection test. Stop dispensing fuel from this tank until CSLD test is complete. Overfill Alarm T Fuel level has exceeded a programmed limit. Potential overflow of tank may occur.
What is a fuel alarm?
Fuel tank alarms provide the tank owner with greater knowledge about the status of their tank contents by warning them of a high/low fluid level, overfill and/or bund leak.
What is PLLD shutdown alarm?
This alarm occurs when the fuel level is below 10 inches and a gross line test has failed. The alarm will clear when the fuel level exceeds 10 inches.
What is a TLS 450?
Description. The TLS-450PLUS Automatic Tank Gauge and Environmental Protection System provides the most comprehensive fuel site data for advanced fuel asset management.
What is a gross line fail alarm?
GROSS LINE FAIL ALARM This alarm occurs when a drop in pump-off line pressure, or low pump-off line pressure is detected.
Can petrol be filled more than tank capacity?
Especially when filling up the car, drivers sometimes doubt if the right amount of fuel is filled for these reasons. So it does when the amount of fuel remained and filled exceeds the capacity of a fuel tank officially indicated by automakers. However if the difference is merely 5~10 liters, this is natural.
What is automatic tank gauge?
An automatic tank gauge (ATG) is an electronic device, whose basic function is to monitor the fuel level in the tank over a period of time to see if the tank is leaking.
How long does a PLLD test take?
The minimum test duration for an Annual test is 45 minutes (30 minutes for the Periodic test and another 15 minutes for LR2).
What is a PLLD shutdown?
Typically, PLLD shutdowns will happen when there is an indication of a potential leak, however they can also happen if your tank runs out of fuel.
What is the leak threshold for annual line tightness testing?
Annual line tightness test must be able to detect a leak at least as small as 0.1 gallons per hour when the line pressure is 1.5 times its normal operating pressure.